Course overviewCourse progress
Module 07 of 08 · Professional

Perfusion and intensification

Four lines of algebra decide most of what a perfusion process is: what it drinks, what it accumulates, how fast the cells must grow, and how much product you throw away to hold the density still.

Module story · 4:20Watched

Four lines of algebra

A three-minute story with two challenges. Walk the retention loop, then price the bleed.

Read the transcript

Both the vessel and the fibre module in this figure are cut open. A fed-batch makes product for a fortnight and then stops. A perfusion feeds fresh medium continuously, removes spent medium continuously, and keeps the cells, so it can hold a high density for weeks.

Three things follow, and only one of them is the obvious one. Output per vessel is the obvious one. Product residence time is less obvious, because product leaves the vessel within a day instead of sitting in warm broth for two weeks. And output per unit of floor space is what actually drives the business case.

The row that matters most in that comparison is the dull one. Specific productivity was about 30 pg per cell per day in all three. Changing the mode changed the density and the volumetric output, and did not change what a cell does. Mode is a lever on the integral, not on productivity per cell. And reject any density above 300 million on sight: the book argues that as a physical limit, from a 53% solid fraction at a 15 µm cell diameter.

Perfusion needs something that lets medium out and keeps cells in. The cells stay in the vessel, and broth leaves its base along a thick line out to the module. Inside, it passes along the outside of hollow fibres. Medium and product cross the membrane and leave as harvest, free of cells. The cells do not cross.

What is left returns to the vessel at the headplate. The number worth memorising is the time broth spends in that loop. It should not be more than about 75 seconds, because outside the vessel there is no oxygen supply and no pH control at all.

Your turn. Tap the part that keeps the cells in while letting medium and product out. Challenge: Which part retains the cells and passes medium and product? Answer: The hollow fibres (3).

There are four families to choose between, and the choice is usually made on which of shear, fouling and scalability you can least afford. Alternating tangential flow pushes broth back and forth across the fibres with a diaphragm, and it is the most widely used option.

There is one failure nobody watches for. Sieving is the ratio of product in the harvest to product in the vessel, and it falls as a membrane fouls, because the membrane starts holding back the product too. Density, viability, lactate and productivity all stay exactly where they were. Only the harvest titre falls, the vessel titre climbs, and the transmembrane pressure creeps up.

This vessel is cut open too, and it has three streams. Fresh medium in from a bottle at the left. The vessel itself, held at a steady density. And harvest out to the right, carrying the product.

And a fourth line, leaving the base for a smaller bottle in front. That is the bleed, and it is what holds the density still. At steady state the specific growth rate equals the bleed rate, so setting that bleed is setting the cells a doubling time. If they cannot hold it, the density will not hold either.

The perfusion rate in vessel volumes per day is the cell specific perfusion rate times the density, divided by 1,000. That allowance is quoted in picolitres per cell per day, and the industrial intensified target is 17 pL/cell/day or below. Read it as a ceiling to get under, not a direction to keep going in. There is a floor below it too, set by how much by-product your clone will tolerate.

Price the bleed. A bleed of 0.3/day costs about 10% of the product at 3 vessel volumes a day. What does it cost at 1? Challenge: Bleed loss = B / D. A bleed of 0.3/day costs 10% at 3 RV/day. What does it cost at 1 RV/day? Options: Less, because there is less medium going through; About thirty per cent, so intensifying makes the bleed hurt more; The same, because the bleed itself has not changed. Answer: About 30%: at a bleed of 0.3/day, loss is 0.3/1. A lower perfusion rate raises the share lost.

Two warnings to carry out. Essentially all the quantitative content in this course's main source sits in one perfusion chapter, so a fed-batch rate is not a perfusion rate and the reverse holds too. And two conventions exist. Per hour with a dimensionless bleed ratio, and per day with bleed as a rate. Mixing them is a factor of twenty-four. Now diagnose the six runs below.

You will be able to

  • Say what perfusion buys and what it costs, in numbers.
  • Work out a perfusion rate, a by-product level and a bleed loss.
  • Choose a retention device knowing what each one trades.
  • Diagnose a perfusion run from its traces.
One-minute decision

In this module

Why run continuously

A fed-batch makes product for a fortnight and then stops. A perfusion feeds fresh medium continuously, removes spent medium continuously, and keeps the cells, so it can hold a high density for weeks. Three things follow, and only one of them is the obvious one.

The obvious one is output per vessel. The less obvious ones are product residence time, because product leaves the vessel within a day instead of sitting in warm broth for two weeks, which matters for anything fragile, and output per unit of floor space, which is what actually drives the business case, because a small vessel running continuously can replace a large one running in campaigns.

The one quantified comparison in this course's sources

Fed-batch
About 22 million cells per mL and a volumetric productivity of 0.34 g/L/day.
Perfusion
About 74 million cells per mL and 2.0 to 2.3 g/L/day.
Concentrated fed-batch
About 117 million cells per mL and the same 2.0 to 2.3 g/L/day. The highest density of the three, and no more output than perfusion.
The row that matters most
Specific productivity was about 30 pg/cell/day in all three. Changing the mode changed the density and the volumetric output and did not change what a cell does. Mode is a lever on the integral, not on productivity per cell, which is the spine of this whole course.
How to read the sixfold ratio
Carefully. 2.2 / 0.34 is 6.5, and the density ratio 74 / 22 is only 3.4, so something else accounts for the remaining factor of about 1.9. It is not run length: a rate in grams per litre per day is already time-normalised. It is that the fed-batch 0.34 is a whole-run average, including the days when there were hardly any cells, while the perfusion 2.2 is a steady-state rate. The honest comparison is a factor of about three, plus an averaging effect.
The density ceiling
Published state of the art is 200 to 250 million cells per mL. The book argues a physical limit near 300 from a 53 per cent solid fraction at a 15 micrometre cell diameter, and says that figure is unpublished. Anything quoted above 300 can be rejected on that argument alone.
What it costs
Medium, continuously, forever. A perfusion at one vessel volume a day drinks its own volume every day, which is why the allowance per cell is the number people fight over.

Source. The mode comparison is Xu et al., reported in Chotteau V et al., in Poertner R (ed.), Biopharmaceutical Manufacturing, Cell Engineering 11, Springer 2023, and it is worth more than most comparisons because it is the same molecule in both modes. The density figures and the ceiling argument are from the same chapter.

A warning about every perfusion number you will read, this course included

Essentially all the quantitative CHO content in this course's main source sits in one chapter, and that chapter is about perfusion. So its rates are perfusion-derived, and the earlier modules of this course were careful to say so when they borrowed one. The reverse caution applies here: a fed-batch rate is not a perfusion rate either.

There is a second trap, and it has cost this project real time. One chapter in the library works in dilution rate per hour with a dimensionless bleed ratio. The perfusion chapter works in vessel volumes per day with bleed as a rate per day. Both are internally consistent. Mixing them is a factor of twenty-four, and the last case in the clinic below is exactly that mistake.

Choose a retention device

Perfusion needs something that lets medium out and keeps cells in. Every option trades shear, fouling and scalability differently, and the choice is usually made on which of those three you can least afford.

A cutaway mammalian bioreactor at the left, full of suspended cells, with a thick silicone line curving from its base across to a cutaway hollow fibre module at the right, and a second line curving back from the top of the module to the vessel headplate. A thinner line leaves the side of the module carrying cell-free harvest away.
3D figureThe loop, and the time cells spend in it

Broth leaves the vessel, passes along the outside of hollow fibres, and returns. Medium and product cross the membrane and leave as harvest; the cells do not. The number worth memorising is the residence time in that loop, about seventy-five seconds, because outside the vessel there is no oxygen supply and no pH control at all.

  1. Vessel, where the cells are retained
  2. Out to the module
  3. Hollow fibres, which pass medium and product and not cells
  4. Back to the vessel
  5. Harvest, free of cells

The families, and what each one trades

  • Alternating tangential flow. A diaphragm pushes broth back and forth across a hollow fibre. Gentle on cells for its throughput and the most widely used option, with one number worth memorising: broth should not spend more than about 75 seconds in the recirculation loop. Outside the vessel there is no oxygen supply and no pH control.
  • Tangential flow. A pump drives broth along the membrane in one direction. Simpler hydraulically, harder on the cells at the pump, and more prone to a fouling layer building on the membrane because the flow never reverses.
  • Settlers and inclined gravity separators. No membrane, so nothing to foul and nothing to shear. Slower, bulkier, and they separate on size, so they preferentially return the large healthy cells and let the small debris leave, which is sometimes an advantage.
  • Acoustic separation. Standing waves aggregate cells so they settle. No membrane and no moving contact with the cells, and it has not scaled far.

The device families and the loop residence threshold come from this course's sources. Anything comparing specific devices or vendors belongs on the site's own reviewed pages rather than in a course, and those are linked below.

Sieving: the failure nobody is watching for

A retention device is meant to retain cells and pass product. The ratio of product in the harvest to product in the vessel is called sieving, and when a membrane starts to foul, sieving falls: the membrane begins holding back the product as well as the cells.

What makes this dangerous is that every culture indicator stays normal. Density, viability, lactate and specific productivity are all exactly where they were. Only the harvest titre falls, the vessel titre climbs, and the transmembrane pressure creeps up, which is why sieving belongs on the daily review and not in a troubleshooting guide. It is the fourth case in the clinic below.

Hold a steady state

This is the part of perfusion that rewards algebra over intuition. Four relations, and between them they tell you what the process drinks, what it accumulates, how fast the cells have to grow and what the bleed costs you. None of them needs a simulation.

A cutaway mammalian bioreactor full of suspended cells at the centre. A medium bottle at the left connects by tubing curving over to the headplate. A harvest bottle at the right is fed by a line curving down from the headplate. A third line leaves the base of the vessel and curves to a smaller bleed bottle in front.
3D figureWhat goes in, what comes out, and what you throw away

Fresh medium in, spent medium and product out, and a deliberate bleed to hold the density still. At steady state the specific growth rate equals the bleed rate, so setting that bleed is setting the cells a doubling time. The product leaving in the bleed is a real loss, and it is the bleed rate divided by the perfusion rate, so intensifying makes it hurt more.

  1. Fresh medium in
  2. The vessel, held at a steady density
  3. Harvest out, carrying the product
  4. Bleed, which holds the density and costs you product
  5. Perfusion rate, in vessel volumes per day

The four relations

Perfusion rate
D = CSPR x VCD / 1000, with the cell-specific perfusion rate in picolitres per cell per day, density in millions of cells per mL, and the result in vessel volumes per day. It is quoted in picolitres throughout the literature, and the industrial intensified target is 17 pL per cell per day or below. Read that as a ceiling to get under rather than a direction to keep going in: there is a floor below it too, set by how much by-product your particular clone will tolerate, and the first case in the clinic is a process that went through it.
Growth at steady state
mu = B. The specific growth rate equals the bleed rate, which is the whole of steady-state perfusion control in one line. Setting a bleed rate is setting the cells a doubling time, and if they cannot hold it the density will not hold either.
By-product at steady state
Cp = qp / CSPR + Cp,in. Concentration rises hyperbolically as the allowance falls, so halving the medium bill doubles the by-product. Lactate rather than ammonia is usually what binds first at a low allowance.
Bleed loss
loss = B / D. The same bleed costs about ten per cent of the product at three vessel volumes a day and about thirty per cent at one. Intensifying makes the bleed hurt more, which is the conclusion nobody expects.

Source. All four from the perfusion chapter in Poertner R (ed.), Cell Engineering 11, Springer 2023. The first was checked against that chapter's own case: 74 million cells per mL at 14 pL per cell per day gives 1.04 vessel volumes a day, and about one vessel volume a day is what a real perfusion runs. Everything here is per DAY, with bleed as a rate.

Intensification most people actually adopt

Full perfusion is a commitment: continuous operation, a retention device to maintain, and a medium supply chain to match. Two intermediate forms get adopted far more often, and both borrow perfusion's density without its operating model.

An N minus one perfusion seed train perfuses the last seed stage so the production vessel can be inoculated at several times the usual density, which shortens the production run. A high-inoculum fed-batch does the same thing from a conventional seed train with more of it.

Both fail the same way, and it is the fifth case in the clinic. Inoculating four times denser into an unchanged feed schedule reaches the same integral sooner and then runs into the osmolality ceiling from Module 4 two days early. Intensification moves the starting point, so the feed profile, the harvest trigger and the osmolality budget all have to move with it.

Diagnose a failed run

Six perfusion runs that went wrong, each built from a mechanism this course has taught. Evidence costs time, so ordering everything is not a winning strategy. The habit worth training is finding the piece that decides it.

Practice and summary

Revisit your opening decision

Open module deck
Confidence by objective

A low rating brings related cards forward for review.

Sources and further reading

Books and chapters

  • Chotteau V, Schwarz H, Maekinen M. Continuous Bioprocessing for Upstream Process: Perfusion Process. In: Poertner R, ed. Biopharmaceutical Manufacturing, Cell Engineering 11. Springer, 2023. The four relations, the cell-specific perfusion rate in picolitres, the intensified target of 17, the mode comparison, the density ceiling argument and the loop residence threshold. This is the strongest chapter in this course's library and essentially all its quantitative CHO content sits in it.
  • Retention-device efficiencies and membrane limits are taken from a second chapter in the same library, which works in dilution rate per hour with a dimensionless bleed ratio. This course works in vessel volumes per day with bleed as a rate, and the two conventions are never mixed. Several figures in that chapter were set aside as unusable: a cycle time given as both 60 and 10 seconds, a table reporting densities on four different volume bases, and a shear comparison whose correct reading is a factor rather than a percentage.
  • Figures 4.4, 4.8 and 4.9 of the perfusion chapter are simulation output sitting among experimental figures, and their inputs are not measurements. Nothing in this module is taken from them.

Related BioProcess Tools pages

Next: assessment and certificate

Perfusion and intensification