Course overviewCourse progress
Module 04 of 06

Contamination Detective

Open a case file, compare independent signals and request the evidence that could change your conclusion.

You will be able to

  • Compare biological, equipment and process explanations for a trace.
  • Choose independent evidence and distinguish the diagnosis from the route of entry.
  • Interpret a modelled detection window using consistent counts and assumptions.
One-minute decision

Work the case files

Read the operator note and align sample, feed and addition times with the traces. Falling oxygen uptake, CO₂ evolution and optical density with a rising DO signal can indicate lysis in a bacterial culture. Verify that feed continued and check independent evidence before attributing lysis to phage. In a flask, filamentous clumps or branching hyphae support mould, while larger budding cells support yeast.

A dark lab worktop with a compound microscope, a clear culture flask beside a turbid one, agar plates with cream colonies, a staining tray holding a slide with a purple Gram-stained smear and four dropper bottles of stain reagents, and a rack of sample tubes.
3D figureThe contamination investigation bench

Pair each process observation with an independent test. Microscopy, plating and a Gram stain can support what a turbid flask only suggests.

  1. Microscope
  2. Clear culture flask
  3. Turbid culture flask
  4. Agar plate with colonies
  5. Gram-stained slide on the staining tray
  6. Sample tube rack

Some mycoplasmas can pass a 0.2 µm filter and affect host growth without obvious turbidity. Routine antibiotics can suppress other signs and mask poor technique. Record both the process observation and the independent test needed to support a diagnosis.

Quick check · 2 questions

Estimate a detection window

Convert the starting count to cells per mL before comparing it with a method’s detection threshold. In the illustrative review below, microscopy is associated with roughly 10⁶ cells/mL and visible turbidity in clear broth with roughly 10⁷/mL. Debris, host biomass and the method change those thresholds. A dense, healthy-looking culture still needs independent purity checks.

Three open agar plates in a row with the same quadrant streak. The first shows no growth, the second shows fine lines of small colonies, and the third shows a dense, nearly confluent first zone, thinner growth in the second zone and isolated colonies in the third.
3D figureOne streak, three incubation times

The same streak checked three times: nothing visible, then small colonies, then clear colonies, heaviest where the streak began. Every detection method has a window before growth can be seen.

  1. Earliest check: no visible growth
  2. Later check: small colonies along the streak
  3. Latest check: clear colonies
  4. Isolated colonies in the last streak zone
Quick check · 2 questions

Practice and summary

Revisit your opening decision

DO · OUR · CER · VCD · STR · detection threshold

Module flashcards
Confidence by objective

A low rating brings related cards forward for review.

Sources and further reading

Books

  • W. L. Hochfeld. Producing Biomolecular Substances with Fermenters, Bioreactors, and Biomolecular Synthesizers. CRC Press, 2006. Chapters 8 and 9, fermenters and bioreactors.
  • Q. Li, C. Reeve, L. Martinez and S. Wright. “Scale-up in Biotechnology.” In M. Moo-Young (ed.), Comprehensive Biotechnology, 3rd ed., vol. 2. Elsevier, 2019. Chapter 2.62, microbiology quality control, pp. 921–923.

Guidance and background

Related BioProcess Tools pages

BioProcess Tools · Aseptic technique · Module 4

Contamination Detective

Takeaways

Check your understanding

Continue to Response and prevention