Course overviewCourse progress
Module 01 of 06

The sterile boundary

Inspect the vessel before a run. Trace each crossing and decide which observations put the setup on hold.

You will be able to

  • Trace the protected path from the gas inlet to the exhaust.
  • Explain what keeps each crossing of the vessel wall aseptic.
  • Decide when the evidence supports putting a run on hold.
One-minute decision

Walk the sterile boundary

Start at the vessel and trace each line to the first protected connection. Look for a dry vent, an intact seal at the headplate and a septum seated flush with its port. Check the assembly against the batch record before accepting it. Sterile describes the absence of viable microorganisms. Aseptic handling protects the culture from unwanted organisms after the intended cells enter.

A benchtop glass bioreactor with its controller, pump tower and addition bottles. Glowing teal rings mark the exhaust filter, the inlet gas filter, the sample valve, the probe and addition ports in the headplate and the caps of the addition bottles.
3D figureWhere the sterile boundary is crossed

Every filter, port, probe and addition line is a place where the sterile boundary is crossed. Walk each one before you accept the assembly.

  1. Exhaust vent filter
  2. Inlet gas filter
  3. Sample valve on the headplate
  4. Addition line entering its feed bottle
  5. Probe port and seal in the headplate
Quick check · 2 questions

Follow a possible source

If one flask is positive, compare its closure, fill and handling history with a matched unaffected flask. A vented cap or suitable plug must allow gas exchange while keeping a dry barrier. Use the checklist below to distinguish a cycle problem from a later transfer or closure problem.

Close-up of a bioreactor headplate. The exhaust filter above the condenser is beaded with condensate and ringed in amber, with more droplets where the condenser outlet meets the filter inlet. An amber arrow runs from outside down through the filter and the condenser bore to the headspace below the headplate. Teal rings mark a feed addition port, the O-ring seal of a probe and the sample valve.
3D figureHeadplate crossings and one ingress route

A vent must keep a dry barrier. Here moist exhaust gas has condensed at the filter inlet and wetted the exhaust filter, and the amber path shows one plausible route through it, down the condenser bore and into the headspace.

  1. Wetted exhaust vent filter
  2. Moist exhaust gas condensing at the filter inlet
  3. Feed addition port
  4. Probe O-ring seal at the headplate
  5. Sample valve and sample line
Why flasks fail sterility: inspection checklist
  • Check the load arrangement. Closed clamps, tightly sealed caps, inverted vessels or tightly packed items can prevent air removal and steam contact.
  • Compare fill level and bottle size with the qualified cycle. Verify the slowest bottle’s recorded temperature and check for boil-over.
  • Inspect the closure and vent for wetting. Examine glass, O-rings and septa for damage or poor seating after cooling.
  • Review the cooled flask’s subsequent handling. Trace each heat-sensitive addition, connection and opening.
  • If several loads are affected, compare cycle printouts, drain condition, steam supply and door-seal history.
Quick check · 2 questions

Practice and summary

Revisit your opening decision

sterile boundary · aseptic · bioburden · closed transfer

Module flashcards
Confidence by objective

A low rating brings related cards forward for review.

Sources and further reading

Books

  • W. L. Hochfeld. Producing Biomolecular Substances with Fermenters, Bioreactors, and Biomolecular Synthesizers. CRC Press, 2006. Chapters 8 and 9, fermenters and bioreactors.
  • W. Klöckner and J. Büchs. “Shake-Flask Bioreactors.” In M. Moo-Young (ed.), Comprehensive Biotechnology, 3rd ed. Elsevier, 2019. Chapter 2.24.
  • C.-F. Mandenius (ed.). Bioreactors: Design, Operation and Novel Applications. Wiley-VCH, 2016. Chapters 1 and 9, vessel design and single-use systems.

Guidance and background

Related BioProcess Tools pages

BioProcess Tools · Aseptic technique · Module 1

The sterile boundary

Takeaways

Check your understanding

Continue to Sterilisation