Feed them less
A three-minute story with two challenges. Find the part that sets the rate, then defend a growth rate setpoint.
Read the transcript
Fed-batch was not invented to feed cells more. It was invented to feed them less. Here is the argument in hardware: a concentrated glucose feed, a pump that meters it, and a vessel cut open to show the broth.
In the early nineteen hundreds bakers' yeast producers found that holding the sugar concentration low on purpose suppressed alcohol and raised the biomass yield. An E. coli run follows the same logic, with acetate in place of alcohol. You keep the culture slightly hungry.
A run has three phases. A batch phase grows cells on the charged medium. A fed-batch phase feeds them until the vessel reaches its maximum working volume. An optional final batch phase runs the residual carbon down.
Through that phase the concentrations in the vessel settle into a quasi-steady state while the total mass of cells and product keeps climbing. The plot looks flat exactly when the vessel is filling with product, because the substrate is consumed about as fast as it arrives.
There are four shapes the pump can follow. A constant flow is simplest, and the growth rate falls continuously. A pulse swings the culture between substrate shock and starvation. An exponential profile holds the specific growth rate where you put it.
The failure mode of a constant feed is documented rather than hypothetical. In one published ergosterol process it left glucose accumulating for the first fifteen hours, then left the culture short of it for the rest of the run. One flow rate cannot be right at both ends.
Your turn. Tap the part of this rig that sets the rate at which substrate arrives. Challenge: Which part sets the rate at which substrate arrives? Answer: The peristaltic pump (2).
If you want the growth rate to stay put, the feed has to grow at the rate the population does. Holding the cells at a chosen growth rate means making so many new grams an hour, and each gram costs 1/Yx/s in glucose. Divide that demand by the concentration in the bottle and you have a flow rate.
Because the population grows exponentially, so must the flow. One warning sits inside the equation. Sf is the glucose concentration in the feed bottle, not in the vessel. It is the commonest substitution error here.
The flow at the end of the phase is not the flow you started with. Biomass rises by exp(µ·tf), and so does the required flow. Check the pump can still deliver there.
The derivation quietly assumed three things, and each is why real runs drift from the plan. A quasi-steady state. A constant yield, which falls as the culture slows. And no maintenance term at all, so the real glucose demand is always higher than this predicts.
A question. The equation will accept any growth rate you give it. Where does published practice put the setpoint for a recombinant E. coli fed-batch? Challenge: Where does published practice put the growth rate setpoint? Options: Near 0.1/h, inside a 0.1 to 0.3 band; Near 0.5/h, around half the maximum; As close to the maximum growth rate as the vessel allows. Answer: Near 0.1/h, inside a 0.1 to 0.3 band.
Two arguments, two mechanisms, one band. Set it lower and you are safe but slow. Set it higher and you buy time at the price of acetate and an oxygen demand your vessel may not meet. Now size a feed against your own vessel below.