Course overviewCourse progress
Module 05 of 08

Oxygen, acetate and heat

Four limits decide how dense your culture can get. One equation and one measured number explain why the published ceilings sit an order of magnitude apart.

Module story ยท 3:16Watched

Four limits, in order

A three-minute story with two challenges. Find what sets the gas rate, then work out what a higher oxygen setpoint costs you.

Read the transcript

Oxygen is the awkward nutrient. Everything else can be dissolved in the medium in advance or pumped in as a concentrated feed. Oxygen is barely soluble, so it has to be delivered continuously at the rate the cells consume it. This vessel is cut open.

Gas enters through a ring sparger below the lowest impeller. The impeller breaks the gas up and disperses it, and the bubbles then carry oxygen up through the broth.

What you actually get is the transfer coefficient multiplied by the gap between saturation and the dissolved concentration you are holding. Hold a higher dissolved oxygen setpoint and that gap is smaller, so the transfer is smaller.

Which gives a very simple ceiling. The vessel transfers oxygen at some maximum rate. Each gram of dry cells demands about 10.8 mmol an hour. Divide the supply by the demand and you have the density at which they exactly meet.

Your turn. Tap the part of this rig that sets how much gas the vessel receives. Challenge: Which part sets how much gas the vessel receives? Answer: The mass flow controller (1).

Take a vessel with a kLa of 400/h. On air at 1 atm it reaches about 9 g/L. On pure oxygen, about 44. On pure oxygen at 4 atm, about 176.

Pure oxygen multiplies the saturation concentration by about 4.8, because air is 21 per cent oxygen. Pressure multiplies it in proportion. One honest wrinkle: the saturation value you assume moves the whole ladder, by about 16 per cent.

A question. Your vessel is oxygen limited, and you raise the dissolved oxygen setpoint. What happens to the density ceiling? Challenge: You raise the dissolved oxygen setpoint. What happens to the density ceiling? Options: It falls, because there is less driving force; It rises, because there is more oxygen in solution; It does not move, because the transfer coefficient is unchanged. Answer: It falls. A higher setpoint leaves less driving force.

Acetate is the signature E. coli failure, and it is routinely misdiagnosed as an aeration problem. It is not. Overflow happens with plenty of oxygen in the vessel, bubbles and all.

The cause is a rate mismatch inside the cell. Sugar is taken up faster than it can be pushed through respiration, and the excess leaves as acetate. Lowering the growth rate setpoint lowers the uptake per cell, and that is the lever that works.

Fix the oxygen and something else takes over. Heat is the one that arrives with size. These two jacketed vessels are cut open, with coolant entering cold low down and leaving warm at the top.

Metabolic heat is released in proportion to oxygen consumed, at roughly 460 kJ per mole, so the load follows the volume. Jacket area follows the square of the linear dimension while volume follows the cube. The bench vessel has plenty of jacket per litre, and the production vessel far less.

In a large microbial fermenter the jacket, not the sparger, is what stops you. So keep the ordering. Oxygen first, then heat as you get bigger, with acetate and carbon dioxide underneath as metabolic rather than physical limits. Now find the binding limit in your own vessel below.

You will be able to

  • Work out the oxygen demand of a culture and the density it allows.
  • Say why acetate appears in a well-aerated vessel.
  • Identify which of four limits binds first, and what moves it.
One-minute decision

In this module

Work out the oxygen demand

Oxygen is the awkward nutrient. Everything else can be dissolved in the medium in advance or pumped in as a concentrated feed. Oxygen is barely soluble, so it has to be delivered continuously at the rate the cells consume it, and that rate rises in proportion to how many cells there are.

A cutaway stirred bench fermenter with two six-blade impellers on a central shaft and a ring sparger beneath the lower one. Bubbles rise in a column through the amber broth. A gas line curves from a mass flow controller reading 2.0 vvm into the headplate.
3D figureGetting oxygen in

Gas enters through a ring sparger below the lowest impeller, which breaks it into bubbles and carries them up through the broth. The transfer you get is the coefficient multiplied by the gap between saturation and the dissolved concentration you are holding. The vessel has a ceiling, and no feed strategy moves it.

  1. Mass flow controller setting the gas rate
  2. Gas inlet through the headplate
  3. Ring sparger
  4. Lower impeller, which breaks and disperses the bubbles
  5. Bubbles carrying oxygen into the broth

Which gives a very simple ceiling. The vessel transfers oxygen at some maximum rate. Each gram of cells demands a known amount per hour. Divide one by the other and you have the density at which supply exactly meets demand.

Key relations and numbers

Density ceiling
X_max = OTR_max / qO2, the supply divided by the demand per gram.
E. coli specific uptake
About 10.8 mmol of oxygen per gram of dry cells per hour, which is 0.35 g of oxygen per gram of cells per hour.
Transfer rate
OTR = kLa times the driving force, the saturation value minus what is held in solution.
Enrichment
Pure oxygen multiplies the saturation concentration by about 4.8, since air is 21 per cent oxygen.
Pressure
Saturation rises in proportion to absolute pressure, so four atmospheres multiplies it again by four.
Physical asymptote
Around 200 g/L dry weight, where cells at about 80 per cent water fill the vessel.

Source. Specific uptake, transfer table and the density bands from Multistage Continuous High Cell Density Culture, Comprehensive Biotechnology 3rd ed., Vol. 2, ch. 2.43, Elsevier 2019. The ladder below is derived from them; the chapter does not compute it.

The ladder

Taking a vessel with kLa 400 per hour, and the chapter's own saturation assumption:

Air, 1 atm gives 100 mmol/L/h, so about 9 g/L. Pure oxygen, 1 atm gives 476, so about 44 g/L. Pure oxygen, 4 atm gives 1,905, so about 176 g/L.

Against the published bands of 5 to 10, 50 to 100 and up to 174 g/L. The ladder brackets them: two of the three land a few grams per litre outside, because no real process runs at exactly that kLa or exactly four atmospheres. What it explains is why the bands sit an order of magnitude apart at all, and the answer is the gas supply and nothing else.

One honest wrinkle. The saturation concentration you assume moves the whole ladder. At 37 degrees, where E. coli actually grows, it is nearer 0.21 mmol/L, which puts the ladder about sixteen per cent below the figures above. The chapter's own table implies about 0.25. Neither is wrong; the difference is what one assumption is worth, and it is worth knowing that a ceiling quoted to two significant figures rests on it.

Keep acetate off the plot

Acetate is the signature E. coli failure. It wastes carbon that should have become cells or product, it inhibits growth as it accumulates, and it is routinely misdiagnosed as an aeration problem. It is not. Overflow happens with plenty of oxygen in the vessel.

The cause is a rate mismatch inside the cell. Sugar is taken up faster than it can be pushed through respiration, and the excess leaves as acetate. Lowering the growth rate setpoint lowers the uptake per cell, and that is the lever that works.

Two framings of the same observation circulate, and they are not identical. One treats it as a ceiling on respiratory capacity, which is the picture the station below uses because it is the one you can act on with a setpoint. The chapter cited at the end of this module explains it instead through competition for metabolic flux and repression of respiratory genes by glucose. Both predict that slowing the culture stops the overflow; they differ on what exactly is saturating, and this course does not pretend that question is settled.

What the sources do and do not give

Mechanism
Explained by flux competition and glucose repression, not by a shortage of oxygen.
Safe setpoint band
Published practice holds the growth rate near 0.1 per hour, capped in a 0.1 to 0.3 band, so acetate stays low. Singh (ed.), Microbial Bioreactors for Industrial Molecules, Wiley 2023.
Measured accumulation
2 to 5 g/L in uncontrolled-pH E. coli flask culture, from the same volume.
Re-consumption
Acetate is taken back up once glucose is exhausted, which is why a trace can fall again late in a run.
Not available
No inhibition threshold and no critical uptake rate appear anywhere in this course's book sources. Anyone quoting one is citing something else.

Find the binding limit

Oxygen is the binding limit in most small vessels, by a wide margin. Fix it, by enriching the gas or raising the pressure, and something else takes over. Which something depends almost entirely on scale.

Two jacketed vessels side by side at the same orientation, the right one about two and a half times the linear size of the left. Each has a pale blue cooling jacket around its straight side, a cold inlet low on the right and a warm outlet high on the right. The larger vessel has visibly less jacket surface for the volume of broth it holds.
3D figureWhy heat binds at scale and not on the bench

Two geometrically similar vessels. The heat a culture makes follows its volume, and the jacket that removes it follows area. Scale the vessel up and volume grows with the cube of the linear dimension while area grows with the square, so the jacket runs out first. Nothing about the biology changed.

  1. Coolant in, cold
  2. Coolant out, warm
  3. Bench vessel: plenty of jacket per litre
  4. Production vessel: the same jacket geometry, far less of it per litre

Heat is the one that arrives with size. Metabolic heat is released in proportion to oxygen consumed, at roughly 460 kilojoules per mole, so heat load scales with volume. Jacket area scales with the square of the linear dimension while volume scales with the cube, so the area available per litre falls as the vessel grows. In a large microbial fermenter the jacket, not the sparger, is what stops you.

Scale-up arithmetic in general, including how to carry a process from one vessel to a much larger one, is the subject of its own course and is not repeated here. What matters for this module is the ordering: oxygen first, then heat as you get bigger, with acetate and carbon dioxide sitting underneath as metabolic rather than physical limits.

Practice and summary

Revisit your opening decision

Open module deck
Confidence by objective

A low rating brings related cards forward for review.

Sources and further reading

Books and chapters

  • Multistage Continuous High Cell Density Culture. In: Moo-Young M, ed. Comprehensive Biotechnology, 3rd ed., Vol. 2, ch. 2.43. Elsevier, 2019. Specific oxygen uptake, the transfer table and the reported density bands.
  • Panikov NS. Microbial Growth Dynamics. Comprehensive Biotechnology, 3rd ed., Vol. 1, ch. 1.18. Elsevier, 2019. Overflow metabolism explained through flux competition and glucose repression.
  • The oxycaloric figure of roughly 460 kJ per mole of oxygen is standard, with published values between about 430 and 480. These chapters name heat removal as a constraint without giving numbers for it.

Related BioProcess Tools pages

Next: induction and product form

Oxygen, acetate and heat