Four limits, in order
A three-minute story with two challenges. Find what sets the gas rate, then work out what a higher oxygen setpoint costs you.
Read the transcript
Oxygen is the awkward nutrient. Everything else can be dissolved in the medium in advance or pumped in as a concentrated feed. Oxygen is barely soluble, so it has to be delivered continuously at the rate the cells consume it. This vessel is cut open.
Gas enters through a ring sparger below the lowest impeller. The impeller breaks the gas up and disperses it, and the bubbles then carry oxygen up through the broth.
What you actually get is the transfer coefficient multiplied by the gap between saturation and the dissolved concentration you are holding. Hold a higher dissolved oxygen setpoint and that gap is smaller, so the transfer is smaller.
Which gives a very simple ceiling. The vessel transfers oxygen at some maximum rate. Each gram of dry cells demands about 10.8 mmol an hour. Divide the supply by the demand and you have the density at which they exactly meet.
Your turn. Tap the part of this rig that sets how much gas the vessel receives. Challenge: Which part sets how much gas the vessel receives? Answer: The mass flow controller (1).
Take a vessel with a kLa of 400/h. On air at 1 atm it reaches about 9 g/L. On pure oxygen, about 44. On pure oxygen at 4 atm, about 176.
Pure oxygen multiplies the saturation concentration by about 4.8, because air is 21 per cent oxygen. Pressure multiplies it in proportion. One honest wrinkle: the saturation value you assume moves the whole ladder, by about 16 per cent.
A question. Your vessel is oxygen limited, and you raise the dissolved oxygen setpoint. What happens to the density ceiling? Challenge: You raise the dissolved oxygen setpoint. What happens to the density ceiling? Options: It falls, because there is less driving force; It rises, because there is more oxygen in solution; It does not move, because the transfer coefficient is unchanged. Answer: It falls. A higher setpoint leaves less driving force.
Acetate is the signature E. coli failure, and it is routinely misdiagnosed as an aeration problem. It is not. Overflow happens with plenty of oxygen in the vessel, bubbles and all.
The cause is a rate mismatch inside the cell. Sugar is taken up faster than it can be pushed through respiration, and the excess leaves as acetate. Lowering the growth rate setpoint lowers the uptake per cell, and that is the lever that works.
Fix the oxygen and something else takes over. Heat is the one that arrives with size. These two jacketed vessels are cut open, with coolant entering cold low down and leaving warm at the top.
Metabolic heat is released in proportion to oxygen consumed, at roughly 460 kJ per mole, so the load follows the volume. Jacket area follows the square of the linear dimension while volume follows the cube. The bench vessel has plenty of jacket per litre, and the production vessel far less.
In a large microbial fermenter the jacket, not the sparger, is what stops you. So keep the ordering. Oxygen first, then heat as you get bigger, with acetate and carbon dioxide underneath as metabolic rather than physical limits. Now find the binding limit in your own vessel below.