One number, measured badly
A three-minute story with two challenges. Find the reading you can trust, then see why a yield from a fast batch undersizes a slow feed.
Read the transcript
One number describes a growing culture. Most people measure it from the wrong part of the curve, with an instrument that stops being honest halfway up.
Specific growth rate is the increase in biomass per unit of biomass already present. The word specific does the work. It is a per-capita rate, which is why a culture can be adding grams faster and faster while its specific growth rate sits perfectly still.
During balanced growth the logarithm of cell density rises in a straight line against time, and the slope of that line is mu. Two readings are enough. More readings across the same window are better, but only if every one of them is inside the exponential phase.
Quick estimate. A culture is measured at a specific growth rate of 0.59/h. About how long does it take to double? Challenge: µ = 0.59/h. About how long is the doubling time? Options: About 35 minutes; About 70 minutes; About 2 hours. Answer: About 70 minutes: td = ln2 / 0.59/h.
Published maxima disagree, and it is worth knowing why. One chapter puts the maximum above 2.5/h on a rich medium, while commonly measured values sit between 1.4 and 2.0/h. On a minimal medium it is below 1.0/h. The maximum depends on what you feed it.
Now the instrument. Optical density is not a measurement of cells. It is a measurement of light that failed to arrive, mostly because it was scattered rather than absorbed. That is a fine proxy for biomass while the suspension is dilute.
The dark cuvette is the neat sample. Read as it is, this dense culture puts 1.40 on the display.
The same culture diluted tenfold reads 0.26, which is 2.6 once you multiply the dilution back. Above about 0.4 the light is scattered more than once on its way through, so the neat reading flattens.
Your turn. Tap the sample whose reading you can actually trust. Challenge: Which sample's reading can you trust? Answer: The tenfold dilution (2), the only sample inside the linear range.
So the rule is short. Dilute into the linear range, read it there, and multiply back. The conversion to dry cell weight belongs to your instrument, your cuvette path length and your strain, so it has to be established rather than borrowed.
The yield coefficient is how many grams of cells you get per gram of substrate consumed. It turns a growth plan into a glucose order, and this is the bottle it sizes, beside a vessel cut open to show the broth.
Cells spend substrate on staying alive before they spend any on growing: maintaining gradients, turning over protein, repairing damage. That spend tracks time rather than growth, so it is a small share of a fast culture's budget and a large share of a slow one. The observed yield falls with the growth rate.
Which leaves one warning for the module after next. A yield measured in a fast batch overstates what you get in a slow fed-batch, so a feed sized on it runs short from the first hour. Now measure a growth rate yourself below.
