Course overviewCourse progress
Module 01 of 08 Free taster

Why scale-up fails

Watch a benchtop tank grow. Decide when a local oxygen inventory can be consumed before the liquid is mixed.

You will be able to

  • Relate vessel size to wall area available per litre.
  • Compare the times for transport and consumption.
  • Interpret a tracer signal in the context of its measurement location.
One-minute decision

Read the change in scale

At fixed proportions, working volume grows with the cube of tank diameter while wetted wall area grows with its square. As the vessel grows, there is less jacket area per litre and more liquid head above the sparger. Compare the time a cell spends between zones with the time that local oxygen supply can support uptake. A controlled bulk DO or pH can conceal excursions elsewhere.

Three bioreactors side by side at true relative size: a tiny glass benchtop bioreactor on a lab bench, a stainless pilot vessel on legs taller than the bench, and a much larger stainless production vessel with a top drive, cooling jacket and an access platform with stairs, next to a grey human figure for scale.
3D figureOne process at three scales

A 2 L benchtop vessel, a 200 L pilot vessel and a 2,000 L production vessel, drawn to the same scale. At fixed proportions, volume grows with the cube of tank diameter while wall area grows only with its square.

  1. 2 L glass benchtop bioreactor on a lab bench
  2. 200 L pilot stainless vessel on legs
  3. 2,000 L production vessel with jacket, top drive and access platform
  4. A 1.75 m person for scale
Quick check · 2 questions

Watch a tracer cross the tank

Circulation time describes a trip around a flow loop. Mixing time describes the decay of concentration differences after an addition. A feed pulse can pass one probe several times before a remote location has settled. In a tall tank, oxygen, substrate, pH and CO₂ can follow different spatial patterns. Bubbles and foam expose cells to a different environment at the surface.

Half-section of a stainless production vessel with three Rushton turbines on one shaft and baffles on the back wall. Violet tracer spreads from a feed point at the liquid surface through the upper zone only, while teal circulation loops above and below each impeller divide the tank into zones. A peristaltic pump on a trolley supplies the feed line.
3D figureA tracer pulse in a 2,000 L vessel

With stacked radial impellers, a tracer added at the surface circulates in the loops of the top impeller before it crosses into the zones below. Each circulation takes time, and bulk mixing can take several circuits.

  1. Feed point at the liquid surface
  2. Tracer still confined to the top impeller zone
  3. Lower loop of the bottom impeller, not yet reached
  4. Bottom Rushton turbine
  5. Tracer feed pump
Quick check · 2 questions

Practice and summary

Revisit your opening decision

geometric similarity · mixing time · circulation time · DO · hydrostatic head

Module flashcards
Confidence by objective

A low rating brings related cards forward for review.

Sources and further reading

Books and chapters

  • K. van’t Riet and R. G. J. M. van der Lans. “Mixing in Bioreactor Vessels.” In M. Moo-Young (ed.), Comprehensive Biotechnology, 3rd ed., vol. 2. Elsevier, 2019. Chapter 2.08.
  • C.-F. Mandenius (ed.). Bioreactors: Design, Operation and Novel Applications. Wiley-VCH, 2016. Chapter 11, P. Neubauer and S. Junne, scale-up and scale-down methodologies.
  • Q. Li, C. Reeve, L. Martinez and S. Wright. “Scale-up in Biotechnology.” In M. Moo-Young (ed.), Comprehensive Biotechnology, 3rd ed., vol. 2. Elsevier, 2019. Chapter 2.62.
  • C. Sieblist et al. “Bioreactor Fluid Dynamics” and M. Müller, “Heat Transfer in Bioreactors.” Comprehensive Biotechnology, 3rd ed., vol. 2, chs. 2.07 and 2.12.

Papers and guidance

Related BioProcess Tools pages

BioProcess Tools · Scale-up and scale-down · Module 1

Why scale-up fails

Takeaways

Check your understanding

Continue to Similarity and scale-up criteria