Biomass and metabolites
Compare optical density with viable biovolume. Judge a metabolite estimate against an independent reference.
You will be able to
- Separate particulate biomass from membrane-intact biovolume.
- Recognise optical, dielectric and fluorescence interferences.
- Align process spectra with reference assays.
Biomass through a death phase
Compare two measurements calibrated against the same initial culture. Scrub through the run. An optical signal can remain large while membrane integrity and viable biovolume decline.
| Reference | What is counted |
|---|---|
| Dry weight | Harvest a known volume, wash and dry to constant mass. Retained solids and salts add positive bias. |
| Optical density | Blank against matching medium. Dilute into the verified linear interval and multiply by the dilution factor. Record path length, instrument and wavelength. |
| Cell count and viability | Microscopy or cytometry counts particles within a defined gate. Dye exclusion measures membrane integrity. Colony formation measures culturability. Clumps and gates affect the result. |
Quick check · 2 questions
Optical, dielectric and fluorescent signals
Transmission falls as particles scatter light out of the beam. Backscatter collects part of the light returning toward the source. Under Mie scattering, particle size, refractive index, angle and wavelength shape the signal. Multiple scattering at high density bends the calibration. Bubbles, dead cells and debris can all contribute.

In the field between the ring electrodes, intact membranes charge and polarise. A dead cell with a broken membrane does not, so the signal tracks viable biovolume. Cells are drawn enlarged.
- Annular platinum electrodes
- Field lines in the broth
- Viable cell in the field, membrane polarised
- Dead cell, leaky membrane, no polarisation
- Insulating probe tip
Across the dielectric β-dispersion, intact membranes charge in a lower-frequency electric field. The increment relative to a higher frequency tracks viable biovolume. Cell size can therefore change the relationship to viable cell count. Membrane breakdown, bubbles, changing conductivity and electrode deposits can affect the signal. A dual-frequency difference reduces some background shifts.
Reduced nicotinamide cofactors emit near 460 nm when excited near 340 nm. The NAD(P)H signal depends on both biomass and redox state. A metabolic shift at constant biomass can therefore resemble growth. Verify the calibration in the intended medium.
Quick check · 2 questions
Metabolites and spectroscopic measurements
At-line analysers measure glucose, lactate or ammonium against standards. Sampling, filtration, queue time and assay duration create delay. A glucose oxidase sensor can detect peroxide electrochemically. Ascorbate or other electroactive species may add current. Check blanks, spike recovery and enzyme activity. Match each reference to the time the sample left the vessel.

The probe window sits in the broth. A fibre-optic cable links the probe to the spectrometer, which displays the Raman spectrum for multivariate calibration.
- Probe tip in the broth; the glow below marks the window
- Raman probe in a headplate port
- Fibre-optic cable
- Spectrometer
- Raman spectrum on screen
| Method | Information and limitation |
|---|---|
| Near infrared (NIR) | Broad, overlapping overtone and combination bands. Water and scattering complicate concentration estimates. |
| Mid infrared (MIR) | Fundamental vibrations give chemical fingerprints. Strong water absorption can require a short optical path. |
| Raman | Inelastically scattered light reports vibrational shifts. Background fluorescence, bubbles and low analyte signal can limit precision. |
| 2D fluorescence | An excitation–emission matrix records several fluorophores at once. Non-fluorescent glucose may be inferred only through correlated process changes. |
These spectra contain more than one source of variation. Multivariate calibration uses measured reference concentrations across representative runs to associate spectral variation with an analyte.
Quick check · 2 questions
Validate a chemometric model
Split whole batches by run, lot and scale before fitting. Fit all transformations on training data. Standard normal variate (SNV) normalises each spectrum. Multiplicative scatter correction (MSC) adjusts offset and scale against a training reference. Derivatives can suppress baseline drift but amplify noise. Choose smoothing and latent factors inside grouped cross-validation.
PLS regresses reference values on latent spectral directions. RMSECV summarises errors during model selection. RMSEP uses untouched prediction batches. Examine bias, residuals across concentration, uncertainty and coverage near the control limit. PCA score distances and residuals can flag extrapolation. A component can track feed composition instead of the intended product.
The enzyme-lot failure
A fluorescence model reported a glucose prediction error of 0.19 g/L. In a held-out run, predicted glucose was about 1 g/L too high. The run used a different enzyme lot and stored medium. The authors proposed these changes as possible explanations for a shift in the indirect fluorescence–glucose relationship. Stop model-driven decisions, confirm reference alignment, then test additional lots as complete held-out batches.
Deploy Raman with an independent check
Acquire a reference at the scan timestamp. Challenge the model with bubbles, density, optical fouling and low glucose. A state estimator can combine Raman-PLS with a material balance and a reference assay. A biased spectrum and a biased model can agree. Use an independent measurement, monitor residuals and specify a fallback.
Quick check · 2 questions
Sources and further reading
- K. Polizzi, “Biosensors”, Comprehensive Biotechnology, 3rd ed., edited by M. Moo-Young, Elsevier, 2019, ch. 1.42.
- J. Glassey, “Multivariate Modeling for Bioreactor Monitoring and Control”, in C.-F. Mandenius (ed.), Bioreactors: Design, Operation and Novel Applications, Wiley-VCH, 2016, ch. 13.
- C. Herwig (ed.), Hybrid Modelling and Multi-Parametric Control of Bioprocesses, MDPI, 2018, Schwab, Lauber and Hesse, chapter on fluorometric in situ monitoring of an E. coli cell factory.
- B. Hitzmann (ed.), Bioprocess Monitoring and Control, MDPI, 2020, Feidl et al., chapter on combining a mechanistic model and Raman spectroscopy during antibody chromatography.
Review and apply
Revisit the opening decision
Module flashcards
Professional review cards
Confidence by objective
Choose low to bring the related cards forward for review.
BioProcess Tools · Module summary
Biomass and metabolites
Key relationships
- OD after dilution = blank-corrected OD × dilution factor within the calibrated range.
- A spectrum paired to an assay represents the sample withdrawal time.
Faults and checks
| Observation | Interpretation or check |
|---|---|
| High OD during loss of viability | Compare membrane integrity and debris against independent samples. |
| Single wavelength rises | Test spectral overlap, background and an independent analyte assay. |
Numbers to remember
- NAD(P)H excitation is near 340 nm and emission near 460 nm.
- Dilution factor 5 converts a blank-corrected OD of 0.20 to an estimated 1.00.